1-WAY SPIDER
• The bolt directly supports the weight of the glass and transmits that load to the spider
• Spiders prevent the transmission of moments by allowing glass to rotate
• Allows for higher heights than common systems to be projected
• The installation of this type of hardware requires professional preparation and placement
• Maximum axial load: 2500 N
• Maximum radial load: 1200 N
• Structural capacity has been verified by laboratory stress tests
• The design of structural loads must be supported by a professional in engineering or architecture.
We guarantee the quality and proper functioning of the product if it was installed correctly.
Made with materials that guarantee a long lifespan.
Clean lines, innovative shapes and impeccable functionality. Experience the future, today.